Progress Update: Liquid Entrainment in Annular Two-Phase Flow in Inclined Pipes

April 8, 2010


Recently, a new capacitance sensor developed in-house was placed in the test section and tested. Results are promising for slug liquid holdup measurement. Two samples for capacitance sensor reading and synchronized high speed camera video have been uploaded to the project page on the TUFFP website (viewing is restricted to member companies). Sample-1 is for VSL = 0.1 m/s and VSG = 0.1 m/s, Sample-2 is for VSL = 0.5 m/s and VSG = 1 m/s.

Back to News & Events